Single point of responsibility
An EnergySystems project manager is accountable for schedule, budget and coordination with the repair facility.
TURBINE SERVICES / OVERHAUL
We manage overhauls of RB211-24G DLE gas generators and other gas turbines, from borescope inspection and the repair decision to restarting the unit at the station: repair-facility selection, acceptance, weekly reports in one format and testing.
Borescope inspection and review of operating data, vibration and maintenance history. We assess the condition and the risks of continued operation.
Deliverable: a report with images and a recommendation: continue operation, repair on site or overhaul.
We prepare a preliminary workscope for modules 01–05 from operating hours, manufacturer bulletins and client requirements, separating mandatory replacements from work that depends on inspection findings.
Deliverable: preliminary workscope, budget and schedule.
We compare facilities on their qualification for the engine type, tooling and test bed, turnaround time, cost and logistics, and agree the choice with the client.
Deliverable: a comparison of offers and a contract with the selected facility.
Gas generator removal within the outage window, preservation, packing in a transport container, customs clearance and delivery to the repair facility.
Deliverable: handover record, photos of condition and completeness, transport documents.
Incoming inspection at the facility, disassembly and inspection of modules and parts. Every replacement and additional repair is agreed with the client, with photos and measurements, before work starts.
Deliverable: a findings report with photos and the final workscope.
Part repair and replacement, rotor balancing and module assembly. Every week the client receives a report in one standard format: work done, photos, deviations and decisions awaiting approval.
Deliverable: weekly reports and minutes of meetings with the repair facility.
Test-bed run at the facility to a programme aligned with manufacturer requirements, witnessed by our engineer and, if the client wishes, a client representative. The documents are checked before shipment.
Deliverable: test report, work report and updated engine records.
Delivery, installation, alignment and system connection, commissioning and start-up support, with monitoring during initial operation.
Deliverable: commissioning certificate and final overhaul report.
The report arrives every week on an agreed day, in the same format throughout the overhaul, so changes are easy to compare.
Minutes of meetings with the repair facility and the list of decisions awaiting your approval are attached.
An EnergySystems project manager is accountable for schedule, budget and coordination with the repair facility.
Additional replacements and repairs go ahead only after your approval, based on photos and inspection data.
Every week you see the status, deviations and the forecast return date of the gas generator.
Inspection findings, test reports, the work report and updated engine records.
Acceptance, parts inspection and repair at the repair facility, installation and start-up at the station.
Our core experience is RB211-24G DLE (SGT-A35) gas generators, including a 2024–2027 contract with Asia Gas Pipeline for the overhaul of nine RB211 gas generators. We also manage overhauls of RT62 power turbines, RFBB36 compressors and GE LM2500+ (PGT25+) drivers.
Send the serial number, operating hours and latest inspection report, and we will prepare a preliminary workscope and schedule.