Our core experience covers Rolls-Royce RB211-24G DLE gas generators in gas compressor packages. We connect field activities, specialist repair facilities and spare parts supply.
Turbine repair & service
Maintenance and repair coordination for gas turbines and gas generators.
Diagnostics and repair scope definition
Gas generator, module and component repairs
Coordination of specialist overhaul facilities
Installation, testing and commissioning support
Condition assessment and repair planning
Inspection findings, operating parameters and maintenance history provide the basis for fault investigation, repair recommendations and maintenance planning.
Review of available operating data and technical reports
Investigation of faults and possible contributing factors
Equipment-specific inspection and maintenance recommendations
Scope, repair-facility involvement and applicable manufacturer requirements are confirmed for each unit from its serial number, operating hours and condition.
We are ready to quote for LM2500 repairs, maintenance and spare parts: condition assessment, field work, coordination of component and unit repairs, and parts procurement for repair programmes.
Other models — on request
We welcome requests for other gas turbine and driver models. We prepare proposals using the model, variant, serial number, operating hours, condition and required scope.
Who overhauls RB211-24G DLE (SGT-A35) gas generators in Kazakhstan?
EnergySystems LLP, based in Almaty, manages overhauls of RB211-24G DLE (SGT-A35) gas generators: inspection, selection of the repair facility and coordination of workshop repairs, spare parts, transport, testing and return of the equipment to site. It holds a 2024–2027 contract with Asia Gas Pipeline for the overhaul of nine RB211 gas generators.
Which gas turbines and compressors does EnergySystems service?
RB211-24G DLE (SGT-A35) gas generators with modules 01–05, RT62 power turbines, RFBB36 pipeline compressors, GE LM2500+ gas generators and PGT25+ drivers, and package auxiliary systems. For each of them: field service, overhaul management, spare parts and controls support.
What does an overhaul managed by EnergySystems include?
Eight stages: inspection and repair decision, workscope by module, selecting the repair facility, removal and transport, incoming inspection and teardown, repair with weekly reports, testing and acceptance, and installation and start-up at the station. Each stage ends with a document, and the client receives a weekly report in the same format.
Does EnergySystems supply spare parts for RB211 and LM2500?
Yes. Enter part numbers from the illustrated parts catalogue (IPC), the engine serial number (ESN) and the required date in the spare parts request form. Parts are bought from manufacturers, their authorised distributors and vetted suppliers, and a part without proof of origin and condition is not supplied.
Does EnergySystems work on site at compressor stations?
Yes. Field service covers borescope and hot-section inspections, vibration assessment, balancing, module exchange and commissioning. Under a 2026–2028 contract the company maintains 22 gas compressor units at seven Asia Gas Pipeline compressor stations.
How do I request a quotation?
Send the equipment model and serial number, the site location, the required scope and the available work window through the enquiry form on the website, to info@energysystems.kz or by phone on +7 777 777 1768.
The two-spool RB211-24G DLE gas generator consists of five modules: Air Intake, Intermediate-Pressure (IP) Compressor, Intermediate Case, High-Pressure (HP) System (HP Compressor, Combustion Chamber, HP Turbine) and Intermediate-Pressure (IP) Turbine. The model is shown in section; “Hide casing” removes the outer casing and external pipework. The separate RT62 power turbine sits downstream of this assembly.
3D / RB211-24G DLE
Loading 3D model…
RB211-24G DLE / GAS GENERATOR5 modules · 2 spools
Drag to orbit · Use + / − to zoom
Cutaway of the RB211-24G gas generator from a CAD model, optimised for viewing in the browser.
Module 01
Air Intake
The gas generator inlet: the nose fairing, the intake casing struts and the variable inlet guide vanes lead air into the IP compressor.
Inlet and guide vane inspection
Variable guide vane actuation checks
Module repair and replacement