EnergySystems
Send enquiry

DIGITAL & CONTROLS

Digital solutions

Industrial automation, SCADA and system integration for process monitoring and equipment operations.

Digital integration services

SCADA & supervisory systems

Process-data acquisition and visualisation, event histories, alerts and operator displays.

    Instrumentation & process control

    Integration of instruments, controllers, engineering systems and equipment within a coordinated control architecture.

      Data for maintenance

      Equipment trends, event logs and technical information to support condition review and maintenance planning.

        Our own turbine service and repair portal

        ENERGYSYSTEMS / SERVICE MANAGEMENT

        Developed by EnergySystems, our portal brings together turbine and equipment history, service and repair planning, defects, technical reports, documentation and team coordination. Used in the AGP (Asia Gas Pipeline) project, it can be adapted for any client’s equipment fleet, workflows, roles and reporting needs. Traceable activities and document control support applicable ISO requirements, OEM procedures and client requirements.

        • Equipment history
        • Maintenance & repair plans
        • Defects & reporting
        • Documents & role-based access

        Digital twins and AI development

        We are developing approaches to digital equipment models and AI-assisted analysis of operating data and technical reports. This is a development direction: the architecture and tools are selected for each client application.

        How data supports an engineer

        Explore the digital service concept: unit readings, deviation-detection logic, engineering review and links to station components.

        Open demonstration
        Demonstration using synthetic data

        All readings, events and history below are illustrative. This is an interface concept with no plant connection or running AI model. It is not a proprietary production SCADA product or a record of client-facility performance.

        INTERFACE CONCEPT

        Equipment-data workflow example

        DEMO-GCU-01 / Unit telemetry

        Engineering review required
        Suction pressure50.2bar
        Discharge pressure75.4bar
        Gas flow3.80M Sm³/day
        Shaft power18.2MW
        Rotor speed5 120rpm
        Unit load72%
        Oil temperature72°C
        Oil pressure3.5bar
        Bearing temperature86°C
        Casing vibration3.2mm/s RMS
        Exhaust temperature486°C
        Filter differential18kPa

        Digital asset record

        DEMO-GCU-01

        Model · Telemetry · History

        Lubrication

        Temperature: 72 °C · Pressure: 3.5 bar

        Linked event: oil temperature rise

        Open component in the 3D model ↗
        ENGINEERING REVIEW LOGIC

        Oil temperature rise at constant load

        A rise of 18 °C at 72% load. Review the measurement, oil-cooler performance and maintenance history. An engineer confirms the cause.

        Recommendation statusPending reviewAn engineer decides on the maintenance action

        Events & maintenance

        Event log
        TimeUnitEventAction
        14:24DEMO-GCU-01Oil temperature +18 °CEngineering review
        14:12DEMO-GCU-02Trend review completeContinue monitoring
        14:00DEMO-GCU-03Unit on standbyReadiness check before start

        From a trend to a maintenance decision

        Explore one example: lubrication-oil temperature rises while the unit load remains constant.

        DEMO-GCU-01 · SCADA
        ParameterBaselineObserved
        Oil supply temperature54 °C72 °C
        Unit load72%72%
        Oil supply pressure3.6 bar3.5 bar
        Demonstration criterion: a rise of at least 15 °C from the example baseline. Actual limits are equipment-specific.

        Digital asset record / DEMO-GCU-01

        System: lubrication

        Data: demonstration snapshots

        Record: temperature deviation under review

        View lubrication system ↗

        01 / SCADA parameters

        Review the operating parameters

        Two observations show oil supply temperature rising from 54 to 72 °C at a constant 72% load. Oil supply pressure changes from 3.6 to 3.5 bar.

        • Compare the observation with its baseline
        • Retain operating context and asset identification

        The trend is linked to the lubrication system in the digital asset record.

        COMPRESSOR STATION / SYSTEMS

        Inside the compression package

        RB211-24G DLE, RT62 power turbine and RFBB36 compressor. The package arrangement follows AGP Kazakhstan OEM references. Select a system to explore our scope of work.

        3D / RB211 / RT62 / RFBB36 package
        RB211 / RT62 / RFBB36 package
        Loading 3D model…
        LAYOUT / COMPRESSION PACKAGERB211 + RT62 + RFBB36

        Drag to orbit · Use + / − to zoom

        01 / Our scope

        Air intake & filtration

        A wide external filter house feeds the elevated inlet duct and intake plenum. This is the turbine air path; transported gas stays in the separate compressor circuit.

        • Filter-element selection and supply
        • Intake, duct and support inspection
        • Air-system installation and maintenance
        Deliverable

        Intake condition report and maintenance scope.

        One compression package and its auxiliaries are shown. Spacing and detail are adapted for viewing; this is not an as-built station plot plan.

        Tell us what your facility needs

        Attach your specification, equipment questionnaire or asset list.

        Send enquiry